Product
Current location:Home>Syringe Pump
Product Name:Wondcon WMV250A Veterinary Syringe Pump
Model:WMV250A
Application:Vet hospital,clinic(dog,cat etc)
Inquiry:

Description of Wondcon WMV250A Veterinary Syringe Pump

DETAILS

Safe, accurate and easy-to-use.

Great for use in veterinary pain management, anesthesia, and oncology areas.

Feature:

Injection accuracy of up to ±2%

Anti-bolus and anti-siphon functions increase patient safety

Various visual and audible alarms

Automatically record historical setting parameters to save clinical operation time

Available change the infusion parameters without interruption of infusion

Keyboard locking function to prevent misoperation

Automatic identification of syringe specifications, suitable for different brand syringes

Button and shuttle key double input mode, to meet different users

Horizontal design allows you to stack multiple pumps on a single IV pole

Four infusion mode for choose

12 months warranty


SPECIFICATION

Syringe Size 

10, 20, 30, 50/60 ml

KVO Rate 

0.1-1 ml/h (in 0.1 ml/h increments)

Applicable Syringe 

Compatible with syringe of any standard 

Drug Library 

Available

VTBI

0.1-9999 ml

<1000 ml in 0.1 ml increments

≥1000 ml in 1 ml increments

Additional Features

Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus,

anti-bolus, system memory

Flow Rate

Syringe 10 ml: 0.1-400 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-900 ml/h

Syringe 50/60 ml: 0.1-1300 ml/h

<100 ml/h in 0.1 ml/h increments

≥100 ml/h in 1 ml/h increments

Infusion mode

Memory mode

Flow rate mode: ml/min, ml/h

Time-based mode

Body weight mode: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

Bolus Rate

Syringe 10 ml: 400 ml/h

Syringe 20 ml: 600 ml/h

Syringe 30 ml: 900 ml/h

Syringe 50/60 ml: 1300 ml/h

Alarm

Occlusion, near empty, end program, low battery, end

battery,AC power off, motor malfunction, system

malfunction, reminder alarm, pressure sensor error,

syringe installation error, syringe drop off

Anti-Bolus 

Automatic 

Accuracy 

±2% (mechanical accuracy ≤1%)

Occlusion

Sensitivity

High, medium, low

Battery

Battery life:7 hours at 5 ml/h

Battery:9.6±1.6 V, rechargeable

Power supply AC:110/230 V (optional), 50/60 Hz, 20 VA

Weight & Size 

2.5 kg,314*167*140 mm

Working Temperature 

Temp:5-40℃, Relative Humidity 20-90%

Safety Classification 

Class Ⅱ, type CF 

Atmospheric Pressure 

860-1060 hpa