Product
Current location:Home>Syringe Pump
Product Name:Wondcon WMV250A Veterinary Syringe Pump
Model:WMV250A
Application:Vet hospital,clinic(dog,cat etc)
Inquiry:

Description of Wondcon WMV250A Veterinary Syringe Pump

DETAILS

Safe, accurate and easy-to-use.

Great for use in veterinary pain management, anesthesia, and oncology areas.

Feature:

● Injection accuracy of up to ±2%

● Anti-bolus and anti-siphon functions increase patient safety

● Various visual and audible alarms

● Automatically record historical setting parameters to save clinical operation time

● Available change the infusion parameters without interruption of infusion

● Keyboard locking function to prevent misoperation

● Automatic identification of syringe specifications, suitable for different brand syringes

● Button and shuttle key double input mode, to meet different users

● Horizontal design allows you to stack multiple pumps on a single IV pole

● Four infusion mode for choose

● 12 months warranty


SPECIFICATION

Syringe Size 

10, 20, 30, 50/60 ml

KVO Rate 

0.1-1 ml/h (in 0.1 ml/h increments)

Applicable Syringe 

Compatible with syringe of any standard 

Drug Library 

Available

VTBI

0.1-9999 ml

<1000 ml in 0.1 ml increments

≥1000 ml in 1 ml increments

Additional Features

Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus,

anti-bolus, system memory

Flow Rate

Syringe 10 ml: 0.1-400 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-900 ml/h

Syringe 50/60 ml: 0.1-1300 ml/h

<100 ml/h in 0.1 ml/h increments

≥100 ml/h in 1 ml/h increments

Infusion mode

Memory mode

Flow rate mode: ml/min, ml/h

Time-based mode

Body weight mode: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

Bolus Rate

Syringe 10 ml: 400 ml/h

Syringe 20 ml: 600 ml/h

Syringe 30 ml: 900 ml/h

Syringe 50/60 ml: 1300 ml/h

Alarm

Occlusion, near empty, end program, low battery, end

battery,AC power off, motor malfunction, system

malfunction, reminder alarm, pressure sensor error,

syringe installation error, syringe drop off

Anti-Bolus 

Automatic 

Accuracy 

±2% (mechanical accuracy ≤1%)

Occlusion

Sensitivity

High, medium, low

Battery

Battery life:7 hours at 5 ml/h

Battery:9.6±1.6 V, rechargeable

Power supply AC:110/230 V (optional), 50/60 Hz, 20 VA

Weight & Size 

2.5 kg,314*167*140 mm

Working Temperature 

Temp:5-40℃, Relative Humidity 20-90%

Safety Classification 

Class Ⅱ, type CF 

Atmospheric Pressure 

860-1060 hpa

Last Article:Wondcon WMV250C Veterinary Syringe Pump
Next article:Wondcon WMV250B Veterinary Syringe Pump
|